Model 2000 Medium Duty Tension tester Hydrajaws RSS news feed service

  Medium Duty
Tension Tester

"Medium Duty Fixing Testers - enabling engineers to confirm the holding power of anchors in most construction materials"




Digital Gauge Operating Instructions

  Remove dust cap from gauge coupler.
  Remove dust cap from tester coupler.
  Pull back ring on tester coupler and insert gauge coupler. Release ring to    complete coupling.
  Press button P to switch gauge on to ‘Normal rise and fall mode’ This will give a    load reading in kN rising as the operating handle on the tester is turned clockwise.    By turning the handle anti clockwise the load will decrease and show the reading    in kN
  To change mode to PEAK HOLD press then P. Display off will appear. Press    twice to display MAX. Press P to display PASS. Press and together until    display until small vertical appears in left hand side of screen. To zero reading    press and wait 2 seconds. Gauge is now in peak hold mode and will display the    maximum load achieved and retain this even when the load has decreased.
  To return to normal mode press then P and display shows MAX. Then press    and display reads OFF. Press P twice and display reads 0. Press and together    until display reads – 000 (The last digit may not read 0 due to ambient    temperature.)
  Press P to switch gauge off


The maximum load capacity of the MAN-SD1S-C transducer at the base of the gauge is 25kn and the gauge should not be loaded above this figure as permanent damage will occur. Eventually the battery will require replacement ( When warning indicator comes on ) and the battery fitted under the removable cover on the back of the gauge. Replace with type PP9 9 volt unit.



Quick Links to Products:

medium duty tension tester | heavy duty range | scaffold tester
eyebolt & ringbolt tester | safety lifeline tester | material bond tester
wall tie tester | long stroke tester | tension meter

Also in this section:

•  Overview
•  Digital Gauge Operating Instructions
•  Applications & Features
•  Hydrajaws 2000 Series Tester
•  Models
•  Accessories


Instructions to Zero Gauge

If the gauge is reading 0.32 for example when no load is applied use the following instructions to re set the display to zero.

Remove the gauge then release any pressure held in the Hydraulic Coupler by pushing in the pin at the base of the coupler.

Press P then down arrow, display = PDU, Press P display = OFF, press P display = PASS, press P display = O, press the up arrow till reading reaches number 5, press P display = ZERO, press P, display = SET, press P = SET, press P display = 5, press P display = 0.00




For further information about our products and services, please click here to contact us.